3
www.fairchildsemi.com
F
μ
C
FM803 Rev. C.3
Absolute Maximum Ratings
Voltage on any terminal relative to GND
V
CC
/RESET
-0.3V to +6.0V
-0.3V to (V
CC
+ 0.3V)
Input Current
20mA
Output Current: /RESET
These are stress ratings only, and functional operation is not implied for these levels or beyond. Exposure to Absolute Maximum Rating
conditions for extended periods may affect device reliability.
20mA
Rate of Rise of V
CC
100V/
μ
s
Continuous Power Dissipation (T
A
= +70
°
C)
SC70-3
174mW
Operating Temperature Range
-40
°
C to +85
°
C
Storage Temperature Range
-65
°
C to +150
°
C
Lead Temperature (soldering, 10s)
+300
°
C
Electrical Characteristics
SC70 Package (T
A
= 25
°
C unless otherwise noted)
V
CC
= full range, as noted under conditions. See Note 1.
Parameter
Symbol
Conditions
Min
Typ
Max
Units
(Note 2)
Operating Voltage
V
CC
T
A
= 0
°
C to +70
°
C
T
A
= -40
°
C to +85
°
C
T
A
= -40
°
C to +85
°
C, V
CC
< 5.5V
FM803J/L/M
T
= -40
°
C to +85
°
C, V
CC
< 3.6V
FM803R/S/T
1.4
1.6
5.5
5.5
V
Supply Current
I
CC
9
15
μ
A
6
10
Reset Threshold
V
TH
FM803L
T
A
= -40
°
C to +85
°
C
T
A
= -40
°
C to +85
°
C
T
A
= -40
°
C to +85
°
C
T
A
= -40
°
C to +85
°
C
T
A
= -40
°
C to +85
°
C
T
A
= -40
°
C to +85
°
C
4.40
4.63
4.86
V
FM803M
4.18
4.38
4.52
FM803J
3.90
4.00
4.18
FM803T
2.97
3.08
3.19
FM803S
2.79
2.93
3.00
FM803R
2.49
2.63
2.70
Reset Threshold Tempco
30
ppm/
°
C
V
CC
to Reset Delay (Note 2)
Reset Active Timout Period
V
CC
= V
TH
to (V
TH
- 100mV)
T
A
= -40
°
C to +85
°
C
10
μ
s
140
256
560
ms
FM803 Output Low
V
OL
V
CC
= V
TH
(min), I
SINK
= 1.2mA,
FM803R/S/T
V
= V
(min), I
SINK
= 3.2mA,
FM803J/L/M
V
CC
= < 1.0V, I
SINK
= 50
μ
A
0.35
V
0.4
0.3
Open-Drain Output Leakage
Current
V
CC
> V
TH
(max), /RESET = 1
7
μ
A
Note 1:
Testing in production is 25
°
C only. V
CC
= 5V for FM803L/M/J, V
CC
= 3.3V for FM803T/S and V
CC
= 3V for FM803R. Limits over temperature are guaranteed by design.
Note 2