Preliminary W89C982AF
- 12 -
The following table summarizes the management commands. The LSBs of both the MSI data and the
MSO data are shown on the right and the MSBs are shown on the left. Each command is described in
more detail below.
MSI INPUT DATA
11010000
11100000
10000000
10001111
11110000
10001111
10001011
10001101
10001001
00111111
00101111
00110bbb
00100bbb
01010bbb
01000bbb
01110bbb
01100bbb
00011111
00010000
00001CSA
MSO READ DATA
P7 . . . P0
P7 . . . P0
P7 . . . P0
P7 . . . P0
M0000000
PBSL0000
PBSL0000
PBSL0000
PBSL0000
None
None
None
None
None
None
None
None
None
None
None
FUNCTIONS
Read link test status of TP ports
Read polarity status of TP ports
Read partition status of TP ports
Read bit rate error status of TP ports
Read MJLP status
Read AUI port status (B, S, L cleared)
Read AUI port status (S, L cleared)
Read AUI port status (B cleared)
Read AUI port status (None cleared)
Enable AUI port
Disable AUI port
Enable TP ports
Disable TP ports
Enable TP port link test function
Disable TP port link test function
Enable TP ports auto polarity reversal function
Disable TP ports auto polarity reversal function
Set AUI port alternate reconnection algorithm
Set TP port alternate reconnection algorithm
Set IMPR II programmable option
Read Link Test Status of TP Ports
The link test status of all eight TP ports can be read using this command. Bits 0 through 7 correspond
to the link test status of TP ports 0 through 7. A "1" on the MSO bit indicates "Link Good" status and a
"0" indicates "Link Fail" status.
Read Polarity Status of TP Ports
The polarity status of all eight TP ports can be read using this command. Bits 0 through 7 correspond
to the polarity status of TP ports 0 through 7. A "1" on the MSO bit indicates reversed polarity and a
"0" indicates positive polarity.
Read Partition Status of TP Ports
The partition status of all eight TP ports can be read using this command. Bits 0
through 7 correspond to the polarity status of TP ports 0 through 7. A "1" on the MSO
bit indicates a connected status and a "0" indicates a partitioned status.
相關PDF資料
PDF描述
W89C982AF INTEGRATED MULTIPLE REPEATER II
W8NB80 N - CHANNEL 800V - 1.2ohm - 7.5A - TO-247 PowerMESH MOSFET
W90100F Embedded Micro-Controller(32位嵌入式的微控制器)
W90210F PA-RISC Embedded Micro-Controller(惠普PA-RISC結構的32位嵌入式微控制器)
W90220F PA-RISC Embedded Micro-Controller(惠普PA-RISC結構的32位嵌入式微控制器)
相關代理商/技術參數
參數描述
W89C982AF 制造商:WINBOND 制造商全稱:Winbond 功能描述:INTEGRATED MULTIPLE REPEATER II
W8C2-DNL 制造商:Hwei Lung Precision Machinery 功能描述:TORCH 8 LED BLACK 2C
W8D10PF29033 制造商:TE Connectivity 功能描述:
W8D11PF29033 制造商:TE Connectivity 功能描述:
W8D16PF29023 制造商:TE Connectivity 功能描述: