W39V040A
- 12 -
Software Product Identification and Boot Block Lockout Detection Acquisition Flow
Product
Identification
Entry (1)
Load data 55
to
address 2AAA
Load data 90
to
address 5555
Pause 10 S
Product
Identification
and Boot Block
Lockout Detection
Mode (3)
Read address = 00000
data = DA
Read address = 00001
data = 3D
Read address = 00002
DQ0/DQ1 of data outputs
= 1/0
(4)
Product
Identification Exit (6)
Load data 55
to
address 2AAA
Load data F0
to
address 5555
Normal Mode
(5)
(2)
(2)
Load data AA
to
address 5555
Load data AA
to
address 5555
Pause 10 S
Notes for software product identification/boot block lockout detection:
(1) Data Format: DQ7
DQ0 (Hex); Address Format: A14
A0 (Hex)
(2) A1
A18 = V
IL
; manufacture code is read for A0 = V
IL
; device code is read for A0 = V
IH
.
(3) The device does not remain in “identification and boot block lockout detection” mode if power down.
(4) The DQ[3:0] to indicate the sectors protect status as below:
DQ0
DQ1
DQ2
DQ3
0
64Kbytes Boot Block
Unlocked by Software
16Kbytes Boot Block
Unlocked by Software
64Kbytes Boot Block Unlocked
by #TBL hardware trapping
Whole Chip Unlocked by #WP hardware
trapping Except Boot Block
1
64Kbytes Boot Block
Locked by Software
16Kbytes Boot Block
Locked by Software
64Kbytes Boot Block Locked by
#TBL hardware trapping
Whole Chip Locked by #WP hardware
trapping Except Boot Block
(5) The device returns to standard operation mode.
(6) Optional 1-write cycle (write F0 hex at XXXX address) can be used to exit the “product identification/boot block lockout
detection.”