28229-DSH-001-B
Mindspeed Technologies
7
-73
CX28224/5/9 Data Sheet
Registers
0x40B—IMA_RCV_LNK_ANOMALIES (IMA Receive Link Anomalies)
These anomalies are for the diagnostic link selected using address 0x409. The bits in
this register are read-only and are cleared upon read.
Bit
Default
Name
Description
7
—
ICP-ERR Anomaly
1 = ICP-ERR anomaly was active sometime since the last time this register was read
0 = ICP-ERR defect was inactive
6
—
ICP-INV Anomaly—
Unexpected IMA
Label
1 = Unexpected IMA Label condition of the ICP-INV anomaly was active sometime
since the last time this register was read
0 = Unexpected IMA Label condition was inactive
5
—
ICP-INV Anomaly—
Unexpected LID
1 = Unexpected LID condition of the ICP-INV anomaly was active sometime since
the last time this register was read
0 = Unexpected LID condition was inactive
4
—
ICP-INV Anomaly—
Unexpected IMA ID
1 = Unexpected IMA ID condition of the ICP-INV anomaly was active sometime
since the last time this register was read
0 = Unexpected IMA ID condition was inactive
3
—
ICP-INV Anomaly—
Unexpected M
1 = Unexpected M condition of the ICP-INV anomaly was active sometime since the
last time this register was read
0 = Unexpected M condition was inactive
2
—
ICP-INV Anomaly—
Unexpected IMA
Frame Number
1 = Unexpected IMA Frame Number condition of the ICP-INV anomaly was active
sometime since the last time this register was read
0 = Unexpected IMA Frame Number condition was inactive
1
—
ICP-INV Anomaly—
Unexpected IMA Cell
Offset
1 = Unexpected IMA Cell Offset condition of the ICP-INV anomaly was active
sometime since the last time this register was read
0 = Unexpected IMA Cell Offset condition was inactive
0
—
ICP-MIS Anomaly
1 = ICP-MIS anomaly was active sometime since the last time this register was read
0 = ICP-MIS defect was inactive