W83877AF
Publication Release Date: Sep. 1996
Preliminary Version 0.50
- 70 -
These are 13-bit registers. Write these registers then the transmitter frame length of a package will be
programmed. These registers are only used in APM=1 (automatic package mode, Set5.Reg4.bit5).
When APM=1, the physical layer will split data stream to a programmed frame length if the
transmitted data is larger than the programmed frame length. When read these registers, they will
return the number of bytes which is not transmitted from a frame length programmed.
4.3.6.5 Set4.Reg6, 7 - Receiver Frame Length (RFRLL/RFRLH)
Reg.
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
RFRLL
bit 7
bit 6
bit 5
bit 4
bit 3
bit 2
bit 1
bit 0
Reset Value
0
0
0
0
0
0
0
0
RFRLH
-
-
-
bit 12
bit 11
bit 10
bit 9
bit 8
Reset Value
-
-
-
0
0
0
0
0
These are 13-bit registers and combined a 13-bit up counter. Program these registers, then the
receiver frame length will be limited to the programmed frame length. If the received frame length is
larger than the programmed receiver frame length, the bit of MX_LEX (Maximum Length Exceed)
will be set to 1. Simultaneously, the receiver will not receive any data to RX FIFO until the next start
flag in the next frame, which is defined in the physical layer IrDA 1.1, is reached and then the
received data begin to write to RX FIFO. Read these registers will return the number of received data
bytes from the receiver for a frame.
4.3.7 Set 5 - Flow control
and
IR control
and
Frame Status FIFO registers
Address
Offset
Register Name
Register Description
0
FCBLL
Flow Control Baud Rate Divisor Latch Register (Low Byte)
1
FCBHL
Flow Control Baud Rate Divisor Latch Register (High Byte)
2
FC_MD
Flow Control Mode Operation
3
SSR
Sets Select Register
4
IRCFG1
Infrared Config Register
5
FS_FO
Frame Status FIFO Register
6
RFRLFL
Receiver Frame Length FIFO Low Byte
7
RFRLFH
Receiver Frame Length FIFO High Byte
4.3.7.1 Set5.Reg0, 1 - Flow Control Baud Rate Divisor Latch Register (FCDLL/ FCDHL)
If occurs flow control from MIR/FIR mode change to SIR mode, then the pre-programming baud rate
of FCBLL/FCBHL are loaded to advanced baud rate divisor latch (ADBLL/ADBHL).